2806C-E18TAG1A 520kw backup diesel generator set
Product Description
- Main Parts: 1. Engine 2. Alternator 3. Controller
- Random Parts:
- output circuit breaker is included
- daily fuel tank eight hours
- bellows
- connection tubing 10 meters
- toolbox
- connecting flange
- camel battery, lead
- spring shock absorber (with pad)
- industrial muffler
- operation manual/installation manual, parts manual
Generator set main specification | |||
Engine Speed |
Working type |
Standard diesel generator set output power |
|
kva |
kwe |
||
1500rmp |
Common use |
591 |
473 |
Standby use |
650 |
520 |
|
Engine brand |
Perkins 2806C-E18TAG1A |
||
Alternator brand |
Stamford |
||
Controller brand |
Smartgen |
||
Cylinder |
6 |
||
Cylinder arrangement |
In-line vertical type |
||
Circulation |
4 stroke |
||
Intake type |
Turbo charge air to air inter-cooler |
||
Combustion system |
Direct injection |
||
Consumption |
211g/kw.h |
||
Compression ratio |
14.5:1 |
||
Cylinder bore*stroke |
145*183mm |
||
Displacement |
15.2L |
||
Direction of rotation |
anti-clockwise direction(from flywheel side) |
||
Cooling system |
Water-cooled |
||
Cooling system capacity |
61L |
||
Lubricating system capacity |
62L |
||
Total genset net weight |
4075kgs |
||
Engine dimension |
2545*1536*1808mm |
||
Genset dimension |
3760*1540*2130mm |
Engine Parts Features
(also can use Volvo engine, Cummins engine, Deutz engine, Mtu engine, Chinese brand engine etc.)
Air inlet system
Mounted air filter
Cooling system
Gear driven circulating pump
Low coolant level switch
Mounted belt driven pusher fan
Radiator incorporating air-to-air charge cooler, (supplied loose)
System designed for ambients up to 50ºC (122ºF)
Electrical equipment
3 level engine protection system
24 volt starter motor and 24 volt 70 amp alternator with DC output
ECM mounted on engine with wiring looms and sensors
Flywheels and flywheel housing
High inertia flywheel to SAE J620 size 18
SAE No. 0 flywheel housing
Fuel system
Fuel cooler
Governing to ISO 8528-5 class G2 with isochronous capability
Mechanically actuated electronically controlled unit fuel injectors with full authority electronic control
Replaceable ‘Ecoplus’ fuel filter elements with primary filter/water separator
Mountings
Front engine mounting bracket
Oil system
Full flow replaceable ‘Ecoplus’ filter
Oil cooler integral with filter header
Wet sump with filler and dipstick
Optional equipment
110 volt/240 volt immersion heater
Additional speed sensor
Air filter rain hood
Temperature and pressure sensors for gauges
Tool kit
Twin starters/facility for second starter
Stamford Alternator Features
(this is optional, like Marathon, Schneider etc.)
1.The 12 outlet terminals of the stator winding can be 2806C-E18TAG1A 520kw backup diesel generator setnected to meet different voltage levels.
2.Advanced automatic voltage regulator to control.
3.Class H insulation meets poor environmental requirements.
4.2/3 of the winding pitch inhibits excessive mid-line current.
5.Single fulcrum or double support structure.
6.Easy to install and maintain.
7.Standard non-maintenance sealed bearings.
8.Standard IP23 protection level.
Smartgen Controller Features
(this is optional,like Deep sea, ComAp etc)
Options as follows
- ATS
- Parallel system
- Oil tank
- Slient box
- Portable slient box
- Water-proof box
- Oil-water seperator
- Lube oil heater
- Coolant heater
- Manual lubricating oil drain pump
- Electric fuel injection pump
- Other diesel generator spare parts
Packaging & Shipping
During the whole production and shipping process, the pictures about the machine and packing will be sent for your reference.
Our Services
1. Pre-sale service
- Professional advice for generator set choice,configuration, installation, investment amount etc. To help you find what you want.
2. Trade-assurance purchase
- We can make deal safe through 2806C-E18TAG1A 520kw backup diesel generator set, because the money, quality and service is guaranteed.
3. Production service:
- Progress of production will be kept informed to our customer.
4. After-sale service:
- Free instructions for installation, debugging, technical support etc. Free parts are available within warranty time.
Welcome to visit our Company!
- Chongqing Jiaxuan Power Equipment Co., Ltd. is a professional diesel generator and spare parts trading company and OEM factory of Cummins, Perkins etc. There are more than 60 professional engineers and technicians, and more than 6000 square meters of modern production and office space.
- We have a variety of imported and domestic high-quality generator, with power 5KW-3500KW(6KVA-4375KVA). It is widely used in banks, industrial buildings, oil fields, school etc. and has been well received by customers both at home and abroad.
FAQ
1. How to choose a proper diesel generator set?
- If you only need a diesel generator as a backup power use with low frequency, there is no important purpose, then I suggest that you choose the low-level configuration type. Because it’s can meet your demand fully.
- If you use the genset once or twice a week, the continuous work time is not too long, then the low-level configuration type may not support your frequent use, for your own benefit I suggest you use the medium configuration Diesel generator sets, so that both can satisfy your needs and cost
- If your diesel generator requires frequent use or long-term operation, you must have a high-configuration type that may be more expensive, but with superior quality and excellent performance can bring the strongest protection to your vital interests.
2. What are the common troubles and troubleshooting solutions?
- the battery is low - check the battery charge.
- the battery cable and plug loose - check and tighten the battery cable and plug.
- the middle of the relay failure - check the relay action
- starter failure - maintenance starter.
- poor oil supply system,not oil - exhaust the air in the fuel system, clear the pipeline to smooth the fuel pump, clean the early filter.
- start the button, start loop poor contact - replace the button, check the start loop.
- nozzle Tsui no oil spray (poor fuel supply) - Check the oil tank to the pump between the oil leakage, blockage.
- the fuel system infiltrated the air - open the exhaust screw to check the oil.
- injection pump injection time is not accurate or fuel pump failure - re-injection pump time.
- governor handle position wrong - when start it,put the governor handle in the no-load position.
- electric circuit board, actuators, speed sensors and other circuit failure - check the relative equipment and circuits.
3. Is there any spare parts you can provide along with the generators to make the maintenance convenient?
- Along with the generator, we will provide flex exhaust pipe, siphon and muffler. Other chargeable parts as filters, belt fuse and relay are available too.
open diesel generator set is powered by series Diesel Engine.2806C-E18TAG1A 520kw backup diesel generator set has the feature of good power performance,safety,low fuel consumption and good reliability.This series generator set is widely used as prime or standby power supply in fieldwork,building,supermarket,industrial and mining factory,oil field,highway,harbour and so on.
JHBJHGJ
open diesel generator set that we provide are all new, each unit all get through the strict production testing.
2806C-E18TAG1A 520kw backup diesel generator set 12 months or 1000 hours(whichever occurs first) of Warranty Time for all our 2806C-E18TAG1A 520kw backup diesel generator set. We take the full responsibility only in the fault that created by the quality, the wearing-parts, daily consumables and human error of operating & maintenance are not included in.