CDLF vertical multistage household water pumps adopts stainless steel AISI304 or 316L, special in high pressure. Impeller,guide vane and all parts contact with liquid are of stainless steel punched and welded, so the flow road is very smooth and prevent producing second pollution. Shaft and sleeve are of hard alloy and adopt wear resistant mechanical seal, having super service time and no-leakage. Electrical motor adopt Y2 aluminum motor, importing bearing,insulation gradef.
Medium:
- Hot and cold clean, non-flammable and non-explosive liquid without solid grain and fibre. If for explosive liquid should choose explosion-proof motor.
- Mineral water, soft water, pure water, edible oil and other light chemical mediums
- When the density or viscosity of liquid is larger than that of water, it is necessary to select a driving motor of high-power
Typical applications:
- Urban water supply and pressure boosting
- Industrial circulating system and processing system
- Water supply for boiler, condensing system, high-rise building or fire fighting system.
- Water treatment and infiltration system
- Agricultural irrigation
- Cooling water system
- Many other domestic and industrial special applications
Electric motor:
- Full-enclosed fan-cooled two-pole standard motor, 50HZ or 60HZ
- Phase: Single-phase or three-phase, standard voltage
- Protection class: IP55, Insulation class: F
50HZ Pump Performance Scope
Model |
CDLF2 |
CDLF4 |
CDLF8 |
CDLF12 |
CDLF16 |
CDLF20 |
CDLF32 |
CDLF42 |
CDLF65 |
CDLF120 |
CDLF150 |
Rated flow[m3/h] |
2 |
4 |
8 |
12 |
16 |
20 |
32 |
42 |
65 |
120 |
150 |
Flow range[m3/h] |
1-3.5 |
1.5-8 |
5-12 |
7-16 |
8-22 |
10-28 |
16-40 |
25-55 |
30-80 |
60-150 |
80-180 |
Max.Pressure[bar] |
23 |
22 |
21 |
22 |
22 |
23 |
26 |
30 |
22 |
16 |
16 |
Motor power[Kw] |
0.37-3 |
0.37-4 |
0.75-7.5 |
1.5-11 |
2.2-15 |
1.1-18.5 |
1.5-30 |
3-45 |
4-45 |
11-75 |
11-75 |
Head range[m] |
8-231 |
6-209 |
13-201 |
14-217 |
16-222 |
6-234 |
4-255 |
11-305 |
8-215 |
15-162.5 |
8.5-157 |
Temperature range[°C] |
-15 -+120 |
||||||||||
Max.Efficiency[%] |
46 |
59 |
64 |
63 |
66 |
69 |
76 |
78 |
80 |
74 |
73 |